testsuite::test_iaf_i0

Command: testsuite::test_iaf_i0


Synopsis
(test_iaf_i0) run -> compares response to internal dc with reference data


Description


test_iaf_i0.sli is a test of a specific feature of the iaf_neuron
model. It is tested whether an internal DC current that is present
from the time of neuron initialization correctly affects the membrane
potential.

This is probably the simplest setup in which we can study how the
dynamics develops from an initial condition.

The expected output is documented and briefly commented at the end of
the script.

When the DC current is supplied by a device external to the neuron
the situation is more complex because additional delays are introduced.


File
testsuite/unittests/test_iaf_i0.sli
Author
February 2004 Diesmann Gewaltig Plesser